Support
Product Testing
Explore five testing methods and the reported results for each order reference.
01 / Test method
Corrosion Resistance Testing
Products undergo a continuous 48-hour salt spray test to evaluate corrosion resistance. After testing, surfaces and mechanical operation are inspected for signs of degradation.

02 / Test method
Environmental Testing
Padlocks are tested in a high-low temperature cycling chamber. The table below lists the reported range by order reference, from −55°C to either +55°C or +80°C. A 24-hour multi-cycle test evaluates operation under temperature changes.

03 / Test method
Drop Testing
Padlocks are dropped more than 10 times from a height of 1.5 meters onto a steel plate to simulate field impacts. Tensile, compression, and bending tests are also used to assess structural strength.

04 / Test method
UV & Climatic Testing
Weatherometer testing simulates exposure to sunlight, moisture, and heat. Accelerated weathering is used to assess whether the padlock shell resists fading, cracking, and chalking.

05 / Test method
Padlock Lifetime Testing
An automated key-cycling system repeats insertion, rotation, and extraction to evaluate wear and mechanical lifespan. Reported cycle results, where available, are listed below.

Test Results by Order Reference
Scroll horizontally to see all columns on smaller screens. A dash means no result was listed in the original table. Test hours are not a service-life estimate.
| Order reference | Salt spray | Temperature range | Drop test | Impact test | UV / climate | Key cycles |
|---|---|---|---|---|---|---|
| 1001 | 48 hours | −55°C to +80°C | More than 10 times | Qualified | 2000 hours | More than 10,000 times |
| 1002 | 48 hours | −55°C to +80°C | More than 10 times | Qualified | 2000 hours | More than 10,000 times |
| 1011 | 120 hours | −55°C to +80°C | More than 10 times | Qualified | 2000 hours | More than 10,000 times |
| 1041 | 48 hours | −55°C to +80°C | More than 10 times | Qualified | 2000 hours | More than 10,000 times |
| 1042 | 48 hours | −55°C to +80°C | More than 10 times | Qualified | 2000 hours | More than 10,000 times |
| 1071 | 120 hours | −55°C to +80°C | More than 10 times | Qualified | 2000 hours | More than 10,000 times |
| 1051 | 120 hours | −55°C to +80°C | More than 10 times | Qualified | 2000 hours | More than 10,000 times |
| 2001 | 48 hours | −55°C to +55°C | More than 10 times | Qualified | 2000 hours | — |
| 2002 | 48 hours | −55°C to +55°C | More than 10 times | Qualified | 2000 hours | — |
| 2021 | 48 hours | −55°C to +55°C | More than 10 times | Qualified | 2000 hours | — |
| 2022 | 48 hours | −55°C to +55°C | More than 10 times | Qualified | 2000 hours | — |
| 2011 | 120 hours | −55°C to +80°C | More than 10 times | Qualified | 2000 hours | — |
| 2012 | 120 hours | −55°C to +80°C | More than 10 times | Qualified | 2000 hours | — |
| 2041 | 120 hours | −55°C to +80°C | More than 10 times | Qualified | 2000 hours | — |
| 2051 | 120 hours | −55°C to +80°C | More than 10 times | Qualified | 2000 hours | — |
| 3001 | 120 hours | −55°C to +55°C | More than 10 times | Qualified | 2000 hours | — |
| 3002 | 120 hours | −55°C to +55°C | More than 10 times | Qualified | 2000 hours | — |
| 3003 | 48 hours | −55°C to +80°C | More than 10 times | Qualified | 2000 hours | — |
| 3004 | 48 hours | −55°C to +80°C | More than 10 times | Qualified | 2000 hours | — |
| 3011 | 120 hours | −55°C to +55°C | More than 10 times | Qualified | 2000 hours | — |
| 3012 | 120 hours | −55°C to +55°C | More than 10 times | Qualified | 2000 hours | — |
| 3013 | 120 hours | −55°C to +55°C | More than 10 times | Qualified | 2000 hours | — |
| 3014 | 120 hours | −55°C to +55°C | More than 10 times | Qualified | 2000 hours | — |
| 3015 | 120 hours | −55°C to +55°C | More than 10 times | Qualified | 2000 hours | — |
| 3031 | 120 hours | −55°C to +80°C | More than 10 times | Qualified | 2000 hours | — |
| 3032 | 120 hours | −55°C to +80°C | More than 10 times | Qualified | 2000 hours | — |
| 3033 | 120 hours | −55°C to +80°C | More than 10 times | Qualified | 2000 hours | — |
| 3034 | 120 hours | −55°C to +80°C | More than 10 times | Qualified | 2000 hours | — |
| 3035 | 120 hours | −55°C to +80°C | More than 10 times | Qualified | 2000 hours | — |
| 4001 | 120 hours | −55°C to +55°C | More than 10 times | Qualified | 2000 hours | — |
| 4002 | 120 hours | −55°C to +55°C | More than 10 times | Qualified | 2000 hours | — |
| 4003 | 120 hours | −55°C to +55°C | More than 10 times | Qualified | 2000 hours | — |
| 4004 | 120 hours | −55°C to +55°C | More than 10 times | Qualified | 2000 hours | — |
| 4011 | 120 hours | −55°C to +55°C | More than 10 times | Qualified | 2000 hours | — |
| 4012 | 120 hours | −55°C to +55°C | More than 10 times | Qualified | 2000 hours | — |
| 4013 | 120 hours | −55°C to +55°C | More than 10 times | Qualified | 2000 hours | — |
| 4021 | 120 hours | −55°C to +55°C | More than 10 times | Qualified | 2000 hours | — |
| 4022 | 120 hours | −55°C to +55°C | More than 10 times | Qualified | 2000 hours | — |
| 4041 | 120 hours | −55°C to +55°C | More than 10 times | Qualified | 2000 hours | — |
| 4042 | 120 hours | −55°C to +55°C | More than 10 times | Qualified | 2000 hours | — |
| 4051 | 120 hours | −55°C to +55°C | More than 10 times | Qualified | 2000 hours | — |
| 4052 | 120 hours | −55°C to +55°C | More than 10 times | Qualified | 2000 hours | — |
| 5001 | 120 hours | −55°C to +55°C | More than 10 times | Qualified | 2000 hours | — |
| 5021 | 120 hours | −55°C to +55°C | More than 10 times | Qualified | 2000 hours | — |
| 5031 | 120 hours | −55°C to +55°C | More than 10 times | Qualified | 2000 hours | — |
| 6021 | 120 hours | −55°C to +80°C | More than 10 times | Qualified | 2000 hours | — |
| 6031 | 120 hours | −55°C to +80°C | More than 10 times | Qualified | 2000 hours | — |
| 6041 | 120 hours | −55°C to +80°C | More than 10 times | Qualified | 2000 hours | — |
| 6042 | 120 hours | −55°C to +80°C | More than 10 times | Qualified | 2000 hours | — |
| 9001 | 120 hours | −55°C to +55°C | More than 10 times | Qualified | 2000 hours | — |